Publication: Bone healing after biodegradable mini-plate fixation
| dc.contributor.authors | Atali, Onur; Gocmen, Gokhan; Aktop, Sertac; Ak, Esin; Basa, Selcuk; Cetinel, Sule | |
| dc.date.accessioned | 2022-03-14T08:14:02Z | |
| dc.date.accessioned | 2026-01-11T10:44:33Z | |
| dc.date.available | 2022-03-14T08:14:02Z | |
| dc.date.issued | 2016-06 | |
| dc.description.abstract | PURPOSE: To compare bone healing in mandibular vertical body osteotomies (MVBO) after fixation with a resorbable 2.0mm-profile fixation system in the first and third postoperative months in rabbits. METHODS: Twenty hemimandibles of ten rabbits were divided into two groups according to duration of resorbable fixation-one or three months. The MVBOs were performed and one four-hole, resorbable, 2.0mm mini-plate fixation system was used on each side. The computed tomography (CT) scans, scanning electron microscopy (SEM), and histomorphometric outcomes of groups I and II were compared. RESULTS: Significant differences were found between the one-and three-month assessments in terms of newly formed bone ratio values (p<0.05). There was more new bone formation at the third month on both the CT and histomorphometric examinations. A better adaptation of the bone tissues to the resorbable mini-plate and screws was observed on SEM at three months. CONCLUSION: The resorbable mini-plates provided a fixation stable enough to allow immediate oral alimentation and callus formation in both groups. | |
| dc.identifier.doi | 10.1590/S0102-865020160060000001 | |
| dc.identifier.eissn | 1678-2674 | |
| dc.identifier.issn | 0102-8650 | |
| dc.identifier.pubmed | 27355742 | |
| dc.identifier.uri | https://hdl.handle.net/11424/241188 | |
| dc.identifier.wos | WOS:000380361700001 | |
| dc.language.iso | eng | |
| dc.publisher | ACTA CIRURGICA BRASILEIRA | |
| dc.relation.ispartof | ACTA CIRURGICA BRASILEIRA | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Absorbable Implants | |
| dc.subject | Tomography, X-Ray Computed | |
| dc.subject | Mandibular Fractures | |
| dc.subject | Osteotomy | |
| dc.subject | Microscopy, Electron Scanning | |
| dc.subject | Rabbits | |
| dc.subject | MANDIBULAR BODY OSTEOTOMY | |
| dc.subject | SPLIT RAMUS OSTEOTOMY | |
| dc.subject | INTERNAL-FIXATION | |
| dc.subject | HISTOMETRIC ANALYSIS | |
| dc.subject | RESORBABLE PLATES | |
| dc.subject | FRACTURES | |
| dc.subject | REPAIR | |
| dc.subject | SCREWS | |
| dc.subject | SYSTEM | |
| dc.subject | ADVANCEMENT | |
| dc.title | Bone healing after biodegradable mini-plate fixation | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 370 | |
| oaire.citation.issue | 6 | |
| oaire.citation.startPage | 364 | |
| oaire.citation.title | ACTA CIRURGICA BRASILEIRA | |
| oaire.citation.volume | 31 |
Files
Original bundle
1 - 1 of 1
