Publication:
Assessment of reliability of three indices measuring gingival overgrowth procjena pouzdanosti triju indeksa za mjerenje hiperplazije gingive

dc.contributor.authorÖZTÜRK ÖZENER, HAFİZE
dc.contributor.authorKURU, LEYLA
dc.contributor.authorsAlkateb A. S., ÖZTÜRK ÖZENER H., KURU L.
dc.date.accessioned2023-07-17T08:59:53Z
dc.date.available2023-07-17T08:59:53Z
dc.date.issued2023-06-01
dc.description.abstractObjectives: Numerous indices have been used to grade the severity of gingival overgrowth which led to suspicion regarding the results concerning its prevalence and pathogenicity. The aim of this study was to assess the concordance of three different gingival overgrowth indices, which were used wide-ly in previous studies, and check their reliability and reproducibility. Material and Methods: A total of 30 full-mouth plaster casts and 90 intra-oral photographs collected from 30 patients diagnosed with gingival overgrowth were included in our study. Three trained examiners performed measurements twice on plaster casts using gingival hyperplasia index (A index) and hyperplastic index (B index). In-traoral photographs were assessed also twice using (C index). Results: Concordance of intra-exam-iner and inter-examiner reliability of the recorded measurements was carried out for each index using weighted kappa (K), with a confidence interval of 95%. The A index revealed intra-examiner total kappa values between 0.724-0.876 for horizontal measurement and 0.512-0.823 for vertical mea-surement, and inter-examiner total kappa values between 0.255-0.626 horizontally and 0.235-0.279 vertically. The B index presented intra-examiner total kappa values between 0.587-0.868 horizontally and 0.653-0.855 vertically; and inter-examiner total kappa values between 0.393-0.595 and 0.372-0.635 for horizontal and vertical measurements, respectively. The C index achieved the highest intra-examiner concordance with total kappa values between 0.758-0.855 and inter-examiner total kappa values between 0.716-0.804. Conclusions: The C index evaluated through intraoral photographs is considered the most reliable and applicable method to be utilized. The C index is suggested to be used in large scale populations with its definite detailed criteria.
dc.identifier.citationAlkateb A. S., ÖZTÜRK ÖZENER H., KURU L., "Assessment of Reliability of Three Indices Measuring Gingival Overgrowth Procjena pouzdanosti triju indeksa za mjerenje hiperplazije gingive", Acta Stomatologica Croatica, cilt.57, sa.2, ss.98-112, 2023
dc.identifier.doi10.15644/asc57/2/1
dc.identifier.endpage112
dc.identifier.issn0001-7019
dc.identifier.issue2
dc.identifier.startpage98
dc.identifier.urihttps://avesis.marmara.edu.tr/api/publication/53e15ceb-b883-4dfc-ac7a-201f955c7d4a/file
dc.identifier.urihttps://hdl.handle.net/11424/291306
dc.identifier.volume57
dc.language.isoeng
dc.relation.ispartofActa Stomatologica Croatica
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectDiş Hekimliği
dc.subjectSağlık Bilimleri
dc.subjectMedicine
dc.subjectDentistry
dc.subjectHealth Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectDENTISTRY, ORAL SURGERY & MEDICINE
dc.subjectGeneral Dentistry
dc.subjectGingival Overgrowth
dc.subjectIndex
dc.subjectInflammation
dc.subjectPhotography
dc.titleAssessment of reliability of three indices measuring gingival overgrowth procjena pouzdanosti triju indeksa za mjerenje hiperplazije gingive
dc.typearticle
dspace.entity.typePublication
local.avesis.id53e15ceb-b883-4dfc-ac7a-201f955c7d4a
local.indexed.atPUBMED
local.indexed.atSCOPUS
relation.isAuthorOfPublication0a9f4732-a3d2-4cea-a27f-93ee4f007f67
relation.isAuthorOfPublicationcc49fe59-fb00-4a6a-a32c-60d68c5f3993
relation.isAuthorOfPublication.latestForDiscovery0a9f4732-a3d2-4cea-a27f-93ee4f007f67

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
5.pdf
Size:
488.07 KB
Format:
Adobe Portable Document Format

Collections