A Non-invasive method for assessment of intravascular fluid status: Inferior vena cava diameters and collapsibility index

Loading...
Thumbnail Image

Date

1969-12-31

Journal Title

Journal ISSN

Volume Title

Publisher

PROFESSIONAL MEDICAL PUBLICATIONS

Research Projects

Organizational Units

Journal Issue

Abstract

Objective: To evaluate the correlation between central venous pressure (CVP) and inferior vena cava (IVC) diameters measured by ultrasonography (Ultrasound) in critically ill patients. Methods: Intubated critically ill patients were enrolled. The CVP values were measured using a U-tube manometer and were compared to the IVC diameters and collapsibility index, which were measured by bedside Ultrasound. Patients younger than 18 years old, who were not intubated, who had an abdominal pressure greater than 12 mmHg, and/or who were admitted for trauma were excluded from the study. Results: Eighty three patients with a mean age of 73.6 +/- 11.2 years were enrolled. The most common diagnosis was sepsis (21 patients, 25.30%). IVC inspiration measurements were statistically significantly correlated with CVP measurements (p0.05, r: 0.1). IVC collapsibility measurements showed a negative correlation with CVP measurements (p<0.01, r: 0.68). Conclusions: There is a strong correlation between CVP and IVC diameters and the collapsibility index. This is a new formula for evaluating CVP, based on our statistical analyses.

Description

Keywords

Ultrasonography, Intubation, End-tidal capnography, SONOGRAPHIC MEASUREMENT, ULTRASONOGRAPHY, CARE, ECHOCARDIOGRAPHY, GUIDELINES, UTILITY, MARKER