Publication:
Diagnosis of Testicular Torsion and Differentiation From Other Pathologies Using Near-Infrared Spectroscopy

dc.contributor.authorŞEKERCİ, ÇAĞRI AKIN
dc.contributor.authorYÜCEL, SELÇUK
dc.contributor.authorÇAM, HAYDAR KAMİL
dc.contributor.authorsAli Üncü Y., ŞEKERCİ Ç. A., YÜCEL S., Sircan-Kucuksayan A., ÇAM H. K., Savaş M., Yıldırım A., Ağras K., Baykara M., CANPOLAT M.
dc.date.accessioned2023-02-20T12:55:07Z
dc.date.available2023-02-20T12:55:07Z
dc.date.issued2023-01-01
dc.description.abstract© 2023 Elsevier Inc.Objective: To develop a near-infrared (NIR) spectroscopy device to diagnose testicular torsion with high sensitivity and specificity. Specifically, we aim to investigate the differentiation between testicular torsion from other pathologies such as orchidoepididymitis, varicocele, and hydrocele. Methods: Two LEDs with wavelengths of 660 nm and 940 nm were used as light sources in the device. Each wavelength was sent to the testicle successively, and a photodiode detected back-reflected diffuse light. The ratio of the light intensities of 660 nm and 940 nm was used as a diagnostic parameter. A multi-center clinical trial was performed in 5 different hospitals. Results: In total, 62 patients in urology clinics with acute testicular pain have been recruited for the study. The developed NIR spectroscopy correctly defined all 8 testicular torsion cases. Besides, 3 orchidoepididymitis, 1 varicocele, and 3 hydrocele cases were correctly distinguished from testicular torsion. Only 1 hydrocele case was misdiagnosed as torsion. The range of the ratio was between 0.14 and 1.16 overall measurements. The ratio varied between 0.14 and 0.3 for the testicle with torsion. The ratio was between 0.49 and 1.16 for the normal testicle and testicle with other pathologies mentioned above. Conclusion: We have chosen the threshold ratio of 0.4 to differentiate between the normal and torsion testis and diagnosed all the torsion cases among all normal and other pathologies. The developed optical device to diagnose testicular torsion is inexpensive, user-friendly, and works based on objective criteria with high sensitivity and specificity in real time.
dc.identifier.citationAli Üncü Y., ŞEKERCİ Ç. A., YÜCEL S., Sircan-Kucuksayan A., ÇAM H. K., Savaş M., Yıldırım A., Ağras K., Baykara M., CANPOLAT M., "Diagnosis of Testicular Torsion and Differentiation From Other Pathologies Using Near-Infrared Spectroscopy", Urology, 2023
dc.identifier.doi10.1016/j.urology.2023.01.004
dc.identifier.issn0090-4295
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85147290475&origin=inward
dc.identifier.urihttps://hdl.handle.net/11424/286646
dc.language.isoeng
dc.relation.ispartofUrology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectDahili Tıp Bilimleri
dc.subjectİç Hastalıkları
dc.subjectNefroloji
dc.subjectSağlık Bilimleri
dc.subjectMedicine
dc.subjectInternal Medicine Sciences
dc.subjectInternal Diseases
dc.subjectNephrology
dc.subjectHealth Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectÜROLOJİ VE NEFROLOJİ
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectUROLOGY & NEPHROLOGY
dc.subjectÜroloji
dc.subjectUrology
dc.titleDiagnosis of Testicular Torsion and Differentiation From Other Pathologies Using Near-Infrared Spectroscopy
dc.typearticle
dspace.entity.typePublication
local.avesis.id5a8969a5-31af-46a0-ac45-d0b67e3fc08f
local.indexed.atPUBMED
local.indexed.atSCOPUS
relation.isAuthorOfPublication1e489bdb-418e-4500-a522-6c0babb604b9
relation.isAuthorOfPublication027c4d90-c7b3-4d6e-9821-b256d1ad46a1
relation.isAuthorOfPublication0c106ff1-322f-462b-b801-f32c03858a19
relation.isAuthorOfPublication.latestForDiscovery1e489bdb-418e-4500-a522-6c0babb604b9

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
324.7 KB
Format:
Adobe Portable Document Format

Collections