Publication: Comparison of the accuracy and reliability of the AmniSure, AMNIOQUICK, and AL-SENSE tests for early diagnosis of premature rupture of membranes
| dc.contributor.authors | Elci, Erkan; Elci, Gulhan Gunes; Sayan, Sena | |
| dc.date.accessioned | 2022-03-12T22:43:32Z | |
| dc.date.accessioned | 2026-01-10T17:05:44Z | |
| dc.date.available | 2022-03-12T22:43:32Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | Objective To compare the accuracy and reliability of the AmniSure, AMNIOQUICK, and AL-SENSE tests with conventional tests to diagnose suspected premature rupture of membranes (PROM). Methods A prospective cohort study of 60 pregnant women at 25-36 weeks of pregnancy with suspected PROM was conducted between January and April 2015. AmniSure (Qiagen Sciences LLC, Germantown, MD, USA), AMNIOQUICK (BIOSYNEX, Strasbourg, France), and AL-SENSE (Common Sense Ltd, Caesarea, Israel) tests were performed after conventional tests (ultrasonography, pooling, nitrazine, and fern tests) and women were followed-up for 7 days. Sensitivity, specificity, and diagnostic accuracy, among others, were assessed and compared. Results For women with a confirmed diagnosis of PROM, the sensitivity and specificity of conventional tests were 93.7% and 100.0%, respectively; diagnostic accuracy was 98.3%. Sensitivity, specificity, and diagnostic accuracy were all 100.0% for AmniSure. Sensitivity, specificity, and diagnostic accuracy for AMNIOQUICK were 75.0%, 97.7%, and 91.6%, respectively. Sensitivity, specificity, and diagnostic accuracy were 75.0%, 86.3%, 83.3%, respectively, for the AL-SENSE pad test. Conclusion The AmniSure test was most sensitive and specific for diagnosing PROM compared with the other tests and is reliable and usable. | |
| dc.identifier.doi | 10.1002/ijgo.13097 | |
| dc.identifier.eissn | 1879-3479 | |
| dc.identifier.issn | 0020-7292 | |
| dc.identifier.pubmed | 31925795 | |
| dc.identifier.uri | https://hdl.handle.net/11424/236333 | |
| dc.identifier.wos | WOS:000510579700001 | |
| dc.language.iso | eng | |
| dc.publisher | WILEY | |
| dc.relation.ispartof | INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | AL-SENSE test | |
| dc.subject | AMNIOQUICK test | |
| dc.subject | AmniSure test | |
| dc.subject | PPROM | |
| dc.subject | Premature rupture of membranes | |
| dc.subject | PROM | |
| dc.subject | PRELABOR RUPTURE | |
| dc.subject | WOMEN | |
| dc.subject | LABOR | |
| dc.title | Comparison of the accuracy and reliability of the AmniSure, AMNIOQUICK, and AL-SENSE tests for early diagnosis of premature rupture of membranes | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 97 | |
| oaire.citation.issue | 1 | |
| oaire.citation.startPage | 93 | |
| oaire.citation.title | INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS | |
| oaire.citation.volume | 149 |