Publication:
Reliability of quantitative ultrasound measurement of flexor digitorum superficialis and profundus muscles in stroke

dc.contributor.authorYAĞCI, İLKER
dc.contributor.authorsKenis-Coskun, Ozge; Giray, Esra; Gencer-Atalay, Zeynep Kardelen; Yagci, Ilker; Karadag-Saygi, Evrim
dc.date.accessioned2022-03-12T22:40:35Z
dc.date.available2022-03-12T22:40:35Z
dc.date.issued2020
dc.description.abstractAim: This study aims to investigate reliability of quantitative ultrasound measurement of the flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) muscles in stroke. Materials & methods: Patients with a history of stroke were recruited. FDP and FDS muscles on both upper extremities were investigated with ultrasound. Two independent assessors acquired images and analyzed them using a program and Heckmatt scale. Results: Forty-eight patients were included. The inter-rater intraclass correlation coefficient for echo intensities was calculated as 0.91 while intrarater intraclass correlation coefficient as 0.80. For Heckmatt scale, the inter-rater reliability for FDS was Kw = 0.74 (p < 0.0005) and for FDP it was Kw = 0.73 (p < 0.0005). Mean echo intensity values showed significant strong correlations with Heckmatt scores (r = 0.663 and r = 0.633 with both p values <0.001). Conclusion: Quantitative ultrasound imaging of FDS and FDP is a reliable method to demonstrate echo intensity changes of muscles in stroke.
dc.identifier.doi10.2217/cer-2020-0105
dc.identifier.eissn2042-6313
dc.identifier.issn2042-6305
dc.identifier.pubmed33325276
dc.identifier.urihttps://hdl.handle.net/11424/235986
dc.identifier.wosWOS:000599189800001
dc.language.isoeng
dc.publisherFUTURE MEDICINE LTD
dc.relation.ispartofJOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectquantitative analysis
dc.subjectreliability
dc.subjectspasticity
dc.subjectstroke
dc.subjectultrasound
dc.subjectINTERRATER RELIABILITY
dc.subjectASHWORTH SCALE
dc.subjectINTEROBSERVER
dc.subjectANGLE
dc.titleReliability of quantitative ultrasound measurement of flexor digitorum superficialis and profundus muscles in stroke
dc.typearticle
dspace.entity.typePublication
local.avesis.id9122c49f-4926-4135-a5ba-cf8f276d5ccf
local.import.packageSS17
local.indexed.atWOS
local.indexed.atSCOPUS
local.indexed.atPUBMED
local.journal.numberofpages8
local.journal.quartileQ4
oaire.citation.endPage1300
oaire.citation.issue18
oaire.citation.startPage1293
oaire.citation.titleJOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH
oaire.citation.volume9
relation.isAuthorOfPublication6da3f4cf-132f-4cd9-bcd8-3775bb1de546
relation.isAuthorOfPublication.latestForDiscovery6da3f4cf-132f-4cd9-bcd8-3775bb1de546

Files

Collections