Publication:
Radiation exposure during different percutaneous renal puncture techniques: A YAU endourology & urolithiasis study

dc.contributor.authorŞENER, TARIK EMRE
dc.contributor.authorTANIDIR, YILÖREN
dc.contributor.authorKÜTÜKOĞLU, MEHMET UMUT
dc.contributor.authorDÖRÜCÜ, DOĞANCAN
dc.contributor.authorsŞENER T. E., TANIDIR Y., Ketenci S., Kutukoglu U., Dorucu D., Cayir H., Pietropaolo A., Emiliani E., Somani B.
dc.date.accessioned2023-09-18T10:55:07Z
dc.date.available2023-09-18T10:55:07Z
dc.date.issued2023-09-01
dc.description.abstractPURPOSE: Radiation exposure is affected by C-arm fluoroscopy device positioning during percutaneous renal puncture. Our aim was to compare the exposure of surgeon\"s lens, hand and chest with a fluoroscopy protocol replicated in different C-arm positions. MATERIALS AND METHODS: A standardized fluoroscopy protocol was created using water-equivalent solid phantoms to replicate a surgeon and patient. 111 mGy radiation (360 s) was applied in standard fluoroscopy mode (91 kVp, 2.7 mA/mAs). Dosimeters were placed on lens, chest and hand of surgeon and patient phantom models. 7 different C-arm positions were created: 0°, mediolateral (ML) +90°, ML -90°, ML +30°, ML -15°, craniocaudal (CC) +30°, CC +15°. Measurements were evaluated separately for different positions. RESULTS: The highest radiation exposure was measured on patient dosimeter (2.97 mSv). The highest exposure on surgeon was recorded on finger dosimeter in all C-arm positions; highest dose was recorded in ML +90° position (2.88 mSv). In finger dosimeters, lowest exposure was recorded in 0° position (0.51 mSv). The lowest exposure of all positions was measured in chest dosimeter in ML -90° position (0.24 mSv). CONCLUSIONS: In positions where X-ray generator of the C-arm was facing towards the surgeon, radiation exposure measured in all dosimeters was higher compared to positions where the generator was facing away. The hand radiation exposure in all positions was higher than chest and lens. Special care must be taken to avoid facing the X-ray generator tube and hands should be as well-protected as chest and eyes with special protective gear.
dc.identifier.citationŞENER T. E., TANIDIR Y., Ketenci S., Kutukoglu U., Dorucu D., Cayir H., Pietropaolo A., Emiliani E., Somani B., "Radiation exposure during different percutaneous renal puncture techniques: A YAU endourology & urolithiasis study", Investigative and clinical urology, cilt.64, sa.5, ss.474-479, 2023
dc.identifier.doi10.4111/icu.20220395
dc.identifier.endpage479
dc.identifier.issn2466-054X
dc.identifier.issue5
dc.identifier.startpage474
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85169846674&origin=inward
dc.identifier.urihttps://hdl.handle.net/11424/293489
dc.identifier.volume64
dc.language.isoeng
dc.relation.ispartofInvestigative and clinical urology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectDahili Tıp Bilimleri
dc.subjectİç Hastalıkları
dc.subjectNefroloji
dc.subjectSağlık Bilimleri
dc.subjectMedicine
dc.subjectInternal Medicine Sciences
dc.subjectInternal Diseases
dc.subjectNephrology
dc.subjectHealth Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectÜROLOJİ VE NEFROLOJİ
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectUROLOGY & NEPHROLOGY
dc.subjectÜroloji
dc.subjectUrology
dc.subjectPercutaneous nephrolithotomy
dc.subjectRadiation exposure
dc.subjectPercutaneous nephrolithotomy
dc.subjectRadiation exposure
dc.titleRadiation exposure during different percutaneous renal puncture techniques: A YAU endourology & urolithiasis study
dc.typearticle
dspace.entity.typePublication
local.avesis.ida7aea6d3-1155-4c44-9577-73a39ef74bde
local.indexed.atPUBMED
local.indexed.atSCOPUS
relation.isAuthorOfPublication5ff4af68-b410-4de6-be8b-a4a80167107e
relation.isAuthorOfPublication86c61091-4762-401c-a1cd-88bb0ea5d84d
relation.isAuthorOfPublication4ab70fe0-967a-4176-ac2b-71acd8e9413e
relation.isAuthorOfPublication1a2a8d2a-fc8e-4320-a014-fa9811d86fcc
relation.isAuthorOfPublication.latestForDiscovery5ff4af68-b410-4de6-be8b-a4a80167107e

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
4.pdf
Size:
4.18 MB
Format:
Adobe Portable Document Format

Collections