Publication:
Er:YAG laser lithium disilicate crown removal: removal time and pulpal temperature change

dc.contributor.authorGÖZNELİ, RİFAT
dc.contributor.authorsGÖZNELİ R., Sendurur T.
dc.date.accessioned2023-07-31T08:17:58Z
dc.date.accessioned2026-01-10T16:51:09Z
dc.date.available2023-07-31T08:17:58Z
dc.date.issued2023-12-01
dc.description.abstractSince the removal of resin-luted all-ceramic restorations is a challenge, the use of Er:YAG lasers has become popular. The aim of this study was to determine the removal time of monolithic lithium disilicate crowns in diferent thicknesses and heat transmission to pulp using Er:YAG laser. Forty-fve full-coverage monolithic lithium disilicate crowns in 1 mm (n = 15), 1.5 mm (n = 15), and mixed thickness (n = 15) were resin luted on relevant extracted human maxillary frst premolars and subjected to Er:YAG laser irradiation for crown removal after 24 h. Laser parameters for each thickness, respectively, were 5 W, 5.6 W, and 5.9 W (10 Hz). The removal time and temperature change values were recorded for each sample. The statistical evaluations were performed using one-way ANOVA variance and post hoc Duncan and Tamhane’s T2 tests (p < 0.05), and Pearson correlation coefcient was used to examine the signifcance within each group and without group discrimination. All crowns were laser-debonded successfully. The removal time (min:s) at the succeeding laser parameter for each group is as follows: between 2:30 and 4:45 at 5 W power for 1-mm samples, between 5:00 and 11:15 at 5.9 W power for 1.5-mm samples, and between 8:45 and 15:00 at 5.9 W power for samples in mixed thickness. Moreover, it was observed that the temperature changes in the pulp chamber did not exceed the critical value of 5.5 °C for any sample. Er:YAG laser irradiation is an efective and safe method for removal of all-ceramic crowns when appropriate laser parameters are used according to thickness. Keywords All-ceramic · Ceramic thickness · Debonding · Heat transmission · Laser parameter
dc.identifier.citationGÖZNELİ R., Sendurur T., "Er:YAG laser lithium disilicate crown removal: removal time and pulpal temperature change", Lasers in Medical Science, cilt.38, sa.1, 2023
dc.identifier.doi10.1007/s10103-023-03832-z
dc.identifier.issn0268-8921
dc.identifier.issue1
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85165323626&origin=inward
dc.identifier.urihttps://hdl.handle.net/11424/291800
dc.identifier.volume38
dc.language.isoeng
dc.relation.ispartofLasers in Medical Science
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectDahili Tıp Bilimleri
dc.subjectDermatoloji
dc.subjectCerrahi Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectMedicine
dc.subjectInternal Medicine Sciences
dc.subjectDermatology
dc.subjectSurgery Medicine Sciences
dc.subjectHealth Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectCERRAHİ
dc.subjectDERMATOLOJİ
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectSURGERY
dc.subjectDERMATOLOGY
dc.subjectCerrahi
dc.subjectSurgery
dc.subjectAll-ceramic
dc.subjectCeramic thickness
dc.subjectDebonding
dc.subjectHeat transmission
dc.subjectLaser parameter
dc.titleEr:YAG laser lithium disilicate crown removal: removal time and pulpal temperature change
dc.typearticle
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
961.36 KB
Format:
Adobe Portable Document Format