Publication:
Cam matriks seramik ve rezin matriks seramik materyallerine termal yaşlandırma işleminin etkisi : bükülme dayanımı, mikrosertlik değerlendirmesi

dc.contributor.advisorKAHRAMANOĞLU, Erkut
dc.contributor.authorÇopun, Mustafa
dc.contributor.departmentMarmara Üniversitesi
dc.contributor.departmentSağlık Bilimleri Enstitüsü
dc.contributor.departmentProtetik Diş Tedavisi Anabilim Dalı
dc.date.accessioned2026-01-16T08:22:17Z
dc.date.issued2025
dc.description.abstractAmaç: Bu in vitro çalışmanın amacı, farklı matriks yapısına sahip 7 farklı cam matriks seramik (Amber Mill, Hassbio, Kore; LiSi, GC, Japonya; Celtro Duo, Dentsply Sirona, Almanya; Tessera, Dentpsly Sirona, Almanya; IPS e.max CAD, Ivoclar, Liechtenstein) ve rezin matriks (Cerasmart, GC, Japonya; Grandio Blocs, VOCO, Almanya) CAD/ CAM materyallerinin bükülme dayanımı, elastik modül, mikrosertlik değerlerini kıyaslamak, 50.000 termosiklus ile yaşlandırma sonrası farklılıkları değerlendirmektir. Gereç ve Yöntem: Tüm CAD/ CAM bloklardan üç nokta bükülme testi için bar şeklinde çubuk (1.2 x 4 x 14 mm) ve yüzey mikrosertlik ölçümleri için ise dikdörtgen (2 mm kalınlığında) şeklinde su altında hassas kesim cihazı (Isomet1000, Buehler, ABD) ile toplam 210 örnek elde edildi. Örneklerin yarısı 50.000 döngü ile 5-55C arasında termal döngü cihazı (SD Mechatronik, Almanya) kullanılarak yaşlandırıldı, diğer yarısı ise 24 saat boyunca 37C distile suda bekletildi. 3 nokta bükülme üniversal test cihazı (AG-X 5kN, Shimadzu, Japonya) kullanılarak gerçekleştirildi, bükülme dayanımı (FS) ve elastik modülüs (EM) hesaplandı. Mikrosertlik ölçümleri (n=5) tamamlandı (Microhardness Tester HMV-2, Shimadzu, Japan) ve Vicker’s mikrosertlik (VHN) değerleri hesaplandı. İstatistiksel analiz için Kruskal-Wallis and Mann-Whitney U testleri kullanıldı, önem düzeyi p<0,05 alındı. Bulgular: Tessera, 24 saat sonra incelenen malzemeler arasında FS (570 MPa), EM (66,2 GPa) ve VHN (717,7) için en yüksek medyan değerlerine sahipken, Cerasmart (FS:260; EM:12,8 ve VHN:99,9) sırasıyla en düşük değerleri sergilemiştir. Hem 24 saat sonra hem de termal yaşlandırma sonrasında FS, EM ve VHN için malzemeler arasında anlamlı bir fark bulunmuştur (p<0.001). Aynı zamanda, termal yaşlandırmanın ardından tüm malzemeler için FS değerlerinde istatistiksel olarak anlamlı bir düşüş olmuştur (p<0.05). Sonuç: Tedavi prosedürü için en uygun CAD/ CAM malzemesini seçerken mekanik özellikleri, malzemeler arasındaki farkları ve yaşlanma sürecinden kaynaklanan potansiyel değişiklikleri göz önünde bulundurmak önemlidir.
dc.description.abstractObjective: The aim of this in vitro study was to examine matrix glass matrix ceramics (Amber Mill, Hassbio, Korea; LiSi, GC, Japan; Celtro Duo, Dentsply Sirona, Germany; Tessera, Dentsly Sirona, Germany; IPS e.max CAD, Ivoclar, Liechtenstein) and resin matrix (Cerasmart, GC, Japan; Grandio Blocs, VOCO, Germany) 7 different blocks to compare the flexural strength, elastic modulus, resilience, surface Vicker's microhardness values and evaluate of the differences after aging with 24 hours and 50.000 thermocycles. Materials and Methods: Bar-shape samples (1.2 x 4 x 14 mm) for the three-point bending test and rectangular (2 mm thickness) samples for the Vicker’s microhardness test, were prepared with a precision cutting device Isomet1000, Buehler, ABD) under water. Half of the samples were aged for 50.000 cycles between 5-55°C using a thermal cycle device (SD Mechatronik, Germany), and the other half were kept in distilled water at 37°C for 24 hours. Three-point bending test (n=10) was performed using a universal testing machine (AG-X 5kN, Shimadzu, Japan) according to ISO 6872:2015. Flexural strength (FS), elastic modulus (EM), resilience (R) values were calculated. Surface microhardness measurements (n=5) were completed (Microhardness Tester HMV-2, Shimadzu, Japan) by 5 repeats from each sample, and Vicker’s microhardness (VHN) values were calculated. Kruskal-Wallis and Mann-Whitney U tests were used for statistical analysis, significance level was set at p<0.05. Results: Tessera had the highest median values for FS (570 MPa), EM (66.2 GPa), and VHN (717.7) among the materials under consideration after 24 hours, while Cerasmart (FS:260; EM:12.8, and VHN:99.9) exhibited the lowest values, respectively. A significant difference was found between the materials for FS, EM, and VHN both after 24 hours and after thermal aging (p<0.001). Concurrently, there was a statistically significant decrease in FS values for all materials following thermal aging (p<0.05). Conclusion: It is crucial to take into account the mechanical properties, the distinctions between materials, and the potential modifications resulting from the aging process when selecting the most appropriate CAD/ CAM material for the treatment procedure.
dc.format.extent[9], 59 sayfa : resim, şekil
dc.identifier.urihttps://katalog.marmara.edu.tr/veriler/yordambt/cokluortam/4C/68a316baa7467.pdf
dc.identifier.urihttps://hdl.handle.net/11424/302855
dc.language.isotur
dc.rightsopenAccess
dc.subjectBükülme dayanımı
dc.subjectcad/ cam
dc.subjectDental prosthesis
dc.subjectDental restoration
dc.subjectDiş protezleri
dc.subjectDiş restorasyonu
dc.subjectelastic modulus
dc.subjectelastik modülü
dc.subjectFlexural strength
dc.subjectlithium disilicate
dc.subjectlityum disilikat
dc.subjectmicrohardness
dc.subjectmikrosertlik
dc.titleCam matriks seramik ve rezin matriks seramik materyallerine termal yaşlandırma işleminin etkisi : bükülme dayanımı, mikrosertlik değerlendirmesi
dc.titleEffect of thermal aging on glass matrix ceramic and resin matrix materials : flexural strength and microhardness evaluation
dc.typedoctoralThesis
dspace.entity.typePublication

Files

Collections